1-866-4 JJSTECH(1-866-455-7832)

Extech EX830 1000A True RMS AC/DC Clamp Meter with IR Thermometer with NISTL

Item #:
EXT-EX830-NISTL
Brand:
Extech
Extech EX830 1000A True RMS AC/DC Clamp Meter with IR Thermometer with NISTL
$299.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech EX830 1000A True RMS AC/DC Clamp Meter with IR Thermometer with NISTL

Extech EX830 1000A True RMS AC/DC Clamp Meter with IR Thermometer with NISTL

$299.99

Discontinued


EX830 1000A True RMS AC/DC Clamp Meter with IR Thermometer with NISTL by Extech

Ideal for industrial applications the 800 series Full size 1000A clamps feature a built-in Infared thermometer and rugged double molded housing

Features

  • Non-contact InfraRed Temperature measurements with laser pointer
  • Models with True RMS Current and Voltage measurements
  • Peak hold captures inrush currents and Transients
  • MultiMeter functions include AC/DC Voltage, Resistance, Capacitance, Frequency, Type K Temperature (EX820/EX830), Diode, and Continuity
  • 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
  • 4000 count backlit display
  • Features include Data Hold and Min/Max
  • Autoranging with manual range button
  • Auto Power off
  • Complete with test leads, 9V battery, general purpose Type K probe (EX820/EX830), and case
  • DC/ AC Current
  • True RMS
  • Type K thermometer
  • DC Zero
General Specifications
Clamp jaw opening 43mm (1.7") approx.
Display 3-3/4 digits (4000 counts) backlit LCD
Continuity check Threshold 40Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage < 3VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication 'OL' displayed
Measurement rate 2 readings per second, nominal
PEAK Captures peaks >1ms
Thermocouple sensor Type K thermocouple required
IR Spectral response 6 to 16µm
IR Emissivity 0.95 fixed
IR distance ratio 8:1
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (AAC and VAC)
AC response True rms (AAC and VAC)
Crest Factor 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100% of range)
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery One (1) 9V Battery (NEDA 1604)
Auto power OFF After approx. 25 minutes
Dimensions & Weight 270x110x50mm (10.6x4.3x2"); 386g (13.6 oz)
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2.
Patent notice U.S. Patent 7163336

Range Specifications
Function
Range & Resolution
Accuracy (% of reading + digits)
AC Current 50/60 Hz
400.0 AAC
± (2.5% + 8d)
1000 AAC
± (2.8% + 5d)
DC Current
400.0 ADC
± (2.5% + 5d)
1000 ADC
± (2.8% + 5d)
AC Voltage 50/60Hz
400.0 mVAC
± (1.0% + 10d)
4.000 VAC
± (1.5% + 5d)
40.00 VAC
400.0 VAC
600 VAC
± (2.0% + 5d)
DC Voltage
400.0 mVDC
± (0.8% + 2d)
4.000 VDC
± (1.5% + 2d)
40.00 VDC
400.0 VDC
600 VDC
± (2.0% + 2d)
Resistance
400.0Ω
± (1.0% + 4d)
4.000kΩ
± (1.5% + 2d)
40.000kΩ
400.0kΩ
4.000MΩ
± (2.5% + 3d)
40.00MΩ
± (3.5% + 5d)
Capacitance
4.000nF
± (5.0% + 30d)
40.00nF
± (5.0% + 20d)
400.0nF
± (3.0% + 5d)
4.000µF
40.00µF
400.0µF
± (4.0% + 10d)
4.000mF
± (10% + 10d)
40.00mF
unspecified
Frequency
4.000kHz
± (1.5% + 2d)
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401Hz to 4000Hz)
Temperature (type-K)
-4 to 1400°F
± (3%rdg + 9°F)
-20 to 760°C
± (3%rdg + 5°C)
Temp (IR)
-58 to -4°F
± 9°F
-4 to 518°F
±2.0% reading or ± 4°F whichever is >
-50 to -20°C
±5°C
-20 to 270°C
±2.0% reading or ±2°C whichever is >

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.