1-866-4 JJSTECH(1-866-455-7832)

Extech EX845 1000A AC/DC True RMS Clamp/DMM with IR Thermometer and Bluetooth MeterLink™

Item #:
EXT-EX845
Brand:
Extech
Extech EX845 1000A AC/DC True RMS Clamp/DMM with IR Thermometer and Bluetooth MeterLink™
$369.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech EX845 1000A AC/DC True RMS Clamp/DMM with IR Thermometer and Bluetooth MeterLink™

Extech EX845 1000A AC/DC True RMS Clamp/DMM with IR Thermometer and Bluetooth MeterLink™

$369.99

Discontinued


EX845 1000A AC/DC True RMS Clamp/DMM with IR Thermometer and Bluetooth MeterLink™ by Extech

Compact size allows measurements in tight locations and Built-in non-contact Voltage detector with LED alert. Three models to choose from with True RMS option and advanced multimeter functions.

Features

  • Built-in non-contact IR Thermometer design with laser pointer
  • METERLiNK Wireless communication with FLIR Thermal Imaging Cameras (b60, i60, B-Series, and T-Series)
  • CAT IV safety rating for industrial applications
  • True RMS Current and Voltage measurements
  • Peak hold captures inrush currents and Transients
  • 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
  • 4000 count backlit display
  • Autoranging with manual range button
  • Data Hold, Min/Max and Auto Power off
  • Complete with CAT IV test leads, 9V battery, general purpose Type K probe, pouch case, and Professional Test Lead Set
General Specifications
Clamp jaw opening 43mm (1.7") approx.
Display 3-3/4 digits (4000 counts) backlit LCD
Continuity check Threshold 40Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage < 3VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication 'OL' displayed
Measurement rate 2 readings per second, nominal
Bluetooth range 10 meters (32 feet) approximately
PEAK Captures peaks >1ms
Thermocouple sensor Type K thermocouple required
IR Spectral response 6 to 16µm
IR Emissivity 0.95 fixed
IR distance ratio 8:1
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (AAC and VAC)
AC response True rms (AAC and VAC)
Crest Factor 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100% of range)
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature 20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery One (1) 9V Battery (NEDA 1604)
Auto power OFF After approx. 10 minutes
Dimensions & Weight 270x110x50mm (10.6x4.3x2"); 386g (13.6 oz)
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category IV 600V and Category III 1000V, Pollution Degree 2.
Patent notice U.S. Patent 7163336

Range Specifications
Function
Range & Resolution
Accuracy (% of reading + digits)
AC Current 50/60 Hz
400.0 AAC
± (2.5% + 8d)
1000 AAC
± (2.8% + 5d)
DC Current
400.0 ADC
± (2.5% + 5d)
1000 ADC
± (2.8% + 5d)
AC Voltage 50/60Hz
400.0 mVAC
± (1.0% + 10d)
4.000 VAC
± (1.5% + 5d)
40.00 VAC
400.0 VAC
1000 VAC
± (2.0% + 5d)
DC Voltage
400.0 mVDC
± (0.8% + 2d)
4.000 VDC
± (1.5% + 2d)
40.00 VDC
400.0 VDC
1000 VDC
± (2.0% + 2d)
Resistance
400.0Ω
± (1.0% + 4d)
4.000kΩ
± (1.5% + 2d)
40.000kΩ
400.0kΩ
4.000MΩ
± (2.5% + 3d)
40.00MΩ
± (3.5% + 5d)
Capacitance
4.000nF
± (5.0% + 30d)
40.00nF
± (5.0% + 20d)
400.0nF
± (3.0% + 5d)
4.000µF
40.00µF
400.0µF
± (4.0% + 10d)
4.000mF
± (10% + 10d)
40.00mF
unspecified
Frequency
4.000kHz
± (1.5% + 2d)
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401Hz to 4000Hz)
Temperature (type-K)
-4 to 1400°F
± (3%rdg + 9°F)
-20 to 760°C
± (3%rdg + 5°C)
Temp (IR)
58 to -4°F
± 9°F
-4 to 518°F
±2.0% reading or ± 4°F whichever is >
-50 to -20°C
±5°C
-20 to 270°C
±2.0% reading or ±2°C whichever is >