1-866-4 JJSTECH(1-866-455-7832)

Extech EX840 1000A AC/DC True RMS Clamp/DMM + IR Thermometer

Item #:
EXT-EX840
Brand:
Extech
Extech EX840 1000A AC/DC True RMS Clamp/DMM + IR Thermometer
$269.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech EX840 1000A AC/DC True RMS Clamp/DMM + IR Thermometer

Extech EX840 1000A AC/DC True RMS Clamp/DMM + IR Thermometer

$269.99

Discontinued


EX840 1000A AC/DC True RMS Clamp/DMM + IR Thermometer by Extech

Ideal for industrial applications, this full-size True RMS 1000A AC/DC Clamp features a built-in Infared Thermometer and rugged double molded housing.

Features

  • Built-in non-contact IR Thermometer with laser pointer
  • True RMS Current and Voltage measurements
  • Peak hold captures inrush currents and Transients
  • MultiMeter functions include AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity
  • 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
  • 4000 count backlit display
  • Features include Data Hold and Min/Max and Auto Power off
  • Autoranging with manual range button
  • Complete with CAT IV test leads, 9V battery, general purpose Type K probe, pouch case, and Professional Test Lead Set

Professional Test Lead Features

  • 8-Piece Professional Test Lead set
  • Two 42" (1m) PVC lead extensions with shrouded banana plugs at both ends
  • Two modular 4" (102mm) Heavy Duty test probe handles with 0.16" (4mm) banana plug tip
  • Two standard size, alligator clips with insulated rubber boot
  • Two extra large, double-insulated, alligator clips with sharp teeth for piercing insulated wire. Jaws open to 0.8" (20mm)

Includes

  • Pouch case to store the meter
  • Temperature probe
  • Test leads
General Specifications
Clamp jaw opening 43mm (1.7") approx.
Display 3-3/4 digits (4000 counts) backlit LCD
Continuity check Threshold 40Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage < 3VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication 'OL' displayed
Measurement rate 2 readings per second, nominal
PEAK Captures peaks >1ms
Thermocouple sensor Type K thermocouple required
IR Spectral response 6 to 16µm
IR Emissivity 0.95 fixed
IR distance ratio 8:1
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (AAC and VAC)
AC response True rms (AAC and VAC)
Crest Factor 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100% of range)
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery One (1) 9V Battery (NEDA 1604)
Auto power OFF After approx. 25 minutes
Dimensions & Weight 270x110x50mm (10.6x4.3x2"); 386g (13.6 oz)
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category IV 600V and Category III 1000V, Pollution Degree 2.
Patent notice U.S. Patent 7163336

Range Specifications
Function
Range & Resolution
Accuracy (% of reading + digits)
AC Current 50/60 Hz
400.0 AAC
± (2.5% + 8d)
1000 AAC
± (2.8% + 5d)
DC Current
400.0 ADC
± (2.5% + 5d)
1000 ADC
± (2.8% + 5d)
AC Voltage 50/60Hz
400.0 mVAC
± (1.0% + 10d)
4.000 VAC
± (1.5% + 5d)
40.00 VAC
400.0 VAC
1000 VAC
± (2.0% + 5d)
DC Voltage
400.0 mVDC
± (0.8% + 2d)
4.000 VDC
± (1.5% + 2d)
40.00 VDC
400.0 VDC
1000 VDC
± (2.0% + 2d)
Resistance
400.0Ω
± (1.0% + 4d)
4.000kΩ
± (1.5% + 2d)
40.000kΩ
400.0kΩ
4.000MΩ
± (2.5% + 3d)
40.00MΩ
± (3.5% + 5d)
Capacitance
4.000nF
± (5.0% + 30d)
40.00nF
± (5.0% + 20d)
400.0nF
± (3.0% + 5d)
4.000µF
40.00µF
400.0µF
± (4.0% + 10d)
4.000mF
± (10% + 10d)
40.00mF
unspecified
Frequency
4.000kHz
± (1.5% + 2d)
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401Hz to 4000Hz)
Temperature (type-K)
-4 to 1400°F
± (3%rdg + 9°F)
-20 to 760°C
± (3%rdg + 5°C)
Temp (IR)
-58 to -4°F
± 9°F
-4 to 518°F
±2.0% reading or ± 4°F whichever is >
-50 to -20°C
±5°C
-20 to 270°C
±2.0% reading or ±2°C whichever is >

Datasheets & User Manuals

Questions & Answers


There are no questions or answers for this item.