Features

  • Full function autoranging DMM includes AC/DC Voltage and Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode and Continuity
  • Current measurements to 2000A through the clamp and 400mA via test leads
  • Large 4000 count backlit display for high resolution and easy viewing in dimly lit areas
  • Basic DCV accuracy of 1% with 0.1mV resolution and current resolution to 0.1μA
  • Rugged 2" (50mm) jaws accomodate one 2000MCM or two 500MCM cables
  • Features include DCA push button zero, Relative measurements and Data Hold
  • Heavy duty ABS case with built-in stand and thumb control function switch
  • Complete with test leads and 9V battery
General Specifications
Conductor Size 2.0”(50mm) maximum
Measurement parameters ACA, DCA, ACV, DCV, Resistance, Diode, Frequency, Capacitance, Duty Cycle, Continuity
Current Sensor Hall Effect
Zero adjust Automatic except for DCA (Push-button)
Diode Test Test current of 0.6mA typical; Open circuit voltage <1.6V DC typical
Battery type 9V NEDA 1604
Range Selection Auto or manual
Display 0.6" (15mm) 5000 Count Backlit LCD
Overload Indication "OL"
Power Consumption 5mA approx
Low Battery Indication Battery icon appears on LCD
Sampling rate 1 reading every 0.35 seconds approx.
Standards CE, IEC 1010-1 CAT III 1000V and CAT IV 600V
Operating Temperature/Humidity 32 to 122°F (0°C to 50°C) / <80%
Dimensions 10 x 2.9 x 1.5" (255 x 73 x 38mm)
Weight 0.85 lbs. (380g)

Maximum Rated Input Limits
Function Maximum Rated Input Limits
AC/DC Current 500mA AC/DC (fused)
AC Voltage 1000 VAC/DC
DC Voltage 1000 VAC/DC
Resistance 400 VAC/DC
Frequency 1000 VAC/DC
Capacitance 400 VAC/DC
Duty Cycle 1000 VAC/DC
Diode Test 400 VAC/DC

Range Specifications
Function Range Resolution Accuracy Remarks
AC/DC Current (Clamp on) 400.0A 0.1A ±(2.0% + 5d) 45Hz to 1KHz
2000A 1A ±(2.0% + 8d)
AC Voltage True RMS 4.000V 1mV ±(1.2% + 5d) 45Hz to 1KHz Input Impedance: 10Mohms
40.00V 10mV
400.0V 0.1V
1000V 1V
DC Voltage 400.0mV 0.1mV ±(0.5% + 2d) Input Impedance: 10Mohms
4.000V 1mV ±(1.0% + 2d)
40.00V 10mV
400.0V 0.1V
1000V 1V
Resistance 400.0 Ω 0.1Ω ±(1.0% + 5d)  
4.000 kΩ
40.00 kΩ 10Ω
400.0 kΩ 100Ω
4.000 MΩ 1kΩ ±(2.0% + 2d)
40.00 MΩ 10kΩ ±(3.5% + 5d)
AC/DC Current (Direct Input) 400.0µA 0.1µA ±(1.2% + 5d) 45Hz to 1KHz
4000µA 1µA
40.00mA 0.01mA
400.0mA 0.1mA
Frequency 5Hz 0.001Hz ±(1% + 5d  
50Hz 0.01Hz
500Hz 0.1Hz
5kHz 1Hz
50kHz 10Hz
100kHz 100Hz
Capacitance 50nF 10pF ±(3% + 5d) Accuracy stated after a relative "REL" zero performed
500nF 100pF
5µF 0.001µF
50µF 0.01µF
Duty Cycle 1 to 99% 0.1% ±(1% + 5d)  
Continuity Audible tone; <10 ohms approximately
Open circuit voltage; 0.5V approximately
 