Discontinued


MA1500 1500A True RMS AC/DC Clamp Meter + NCV by Extech

Features

  • True RMS for accurate readings of non-sinusoidal waveforms
  • Built-in non-contact Voltage detector with LED alert
  • 2.0" (52mm) jaw size for conductors up to 500MCM
  • Dual 40,000/4000 count, backlit LCD display
  • Includes Multimeter functions
  • Inrush function captures transients during motor startups
  • Relative Mode for Capacitance Zero and Offset Adjustment
  • Data Hold, Peak Hold, MIN/MAX, and Auto Power Off
  • Complete with test leads, general purpose Type K bead wire temperature probe, 9V battery and carrying case
General Specifications
Clamp jaw opening 52mm (2.0") approx.
Display Dual 40,000/4,000 count backlit LCD
Continuity check Threshold 25 to 60Ω; Test current < 0.5mA
Diode test Test current of 0.3mA typical;
Open circuit voltage 2.8VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication 'OL' display
Measurement rate 2 readings per second, nominal
Peak detector >1ms
Thermocouple sensor Type K thermocouple required
Input Impedance 10MΩ (VDC and VAC)
AC bandwidth 50 to 400Hz (AAC and VAC)
AC response True rms (AAC and VAC)
Crest Factor 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100% of range)
Operating Temperature 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 2000meters (7000ft) maximum.
Battery One (1) 9V Battery (NEDA 1604)
Auto power OFF After approx. 30 minutes
Dimensions & Weight 294x105x47mm (11.57x4.13x1.85"); 536g (18.9 oz)
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category IV 600V and Category III 1000V, Pollution Degree 2.
Approvals CE

Range Specifications
Function
Range& Resolution
Accuracy (% of reading)
DC Current
400.00 ADC
± (2.0% +30digits)
1500.0 ADC
± (2.5% +30digits)
AC Current True RMS (50Hz to 60 Hz)
400.00 AAC
± (2.8% +30digits)
1500.0 AAC
All AC current ranges are specified from 5% to 100% of range
DC Voltage
400.00 mVDC
± (0.1% + 5 digits)
4.0000 VDC
± (0.1% + 4 digits)
40.000 VDC
400. 00 VDC
1000.0 VDC
± (0.5% + 4 digits)
AC Voltage True RMS (50 Hz to 1000 Hz)
400.00 mVAC
± (0.8% + 40 digits)(50/60Hz)
4.0000 VAC
± (1.0% + 30 digits)
40.000 VAC
400. 00 VAC
750.0 VAC
All AC voltage ranges are specified from 5% to 100% of range
Resistance
400.00 Ω
± (0.5% + 9 digits)
4.0000 kΩ
± (1.0% + 4 digits)
40.000 kΩ
400.00 kΩ
4.0000 MΩ
± (2.0% + 10 digits)
40.000 MΩ
± (3.0% + 10 digits)
Capacitance
400.00 nF
±(3.5% reading + 40 digits)
4000.0 nF
±(3.5% reading + 10 digits)
40.00.μF
400.0.μF
4.000 mF
±(5% reading + 10 digits)
20.00 mF
40.00 mF
Not specified
Frequency
40.000 Hz
±(0.3% reading + 2 digits)
400.00 Hz
4.0000 kHz
40.000 kHz
400.00 kHz
4.0000MHz
40.000MHz
Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms min @ 20% to 80% duty cycle and > 100kHz.
Duty Cycle
10.0 to 95.0%
± (1.0% reading + 2 digits)
Pulse width: 100µs - 100ms, Frequency: 10Hz to 100kHz
Temp (type-K)
-100.0 to 1000.0°C
±(1.0% reading + 2.5 °C)
-148.0 to 1832.0°F
±(1.0% reading + 4.5°F)
probe accuracy not included)