Features

  • True RMS for accurate readings of non-sinusoidal waveforms
  • Built-in non-contact Voltage detector with LED alert
  • 1.5" (40mm) jaw size for conductors up to 500MCM
  • 6000 count, backlit LCD display
  • Includes Multimeter functions
  • Model MA640 measures DC Current
  • Relative Mode for Capacitance Zero and Offset Adjustment
  • Data Hold, MIN/MAX, and Auto Power Off
  • Complete with test leads, general purpose Type K bead wire temperature probe, 9V battery and carrying case
General Specifications
Clamp jaw opening 1.5" (40mm) approx.
Display 6000 count backlit LCD
Continuity check Threshold 60Ω; Test current < 0.35mA
Diode test Test current of 0.9mA typical;
Open circuit voltage [ 2.8VDC typical
Low Battery indication Battery symbol is displayed
Over-range indication 'OL' display
Measurement rate 2 readings per second, nominal
Thermocouple sensor Type K thermocouple required
Input Impedance 10MΩ (VDC and VAC)
AC current bandwidth 50/60Hz
AC voltage bandwidth 50 to 400Hz
AC response True rms (AAC and VAC)
Crest Factor 3.0 in 60A and 600A ranges, (50/60Hz and 5% to 100% of range)
Operating Temperature 41°F to 104°F (5°C to 40°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Operating Humidity Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C)
Storage Humidity <80%
Operating Altitude 7000ft. (2000meters) maximum.
Battery One (1) 9V Battery (NEDA 1604)
Auto power OFF After approx. 15 minutes, with disable
Dimensions & Weight 9.2x3x1.53" (232x77x39mm); 9.56 oz. (271g)
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2.
Approvals CE

Range Specifications
Function
Range
Resolution
Accuracy (% of reading + digits)
AC Current 50/60 Hz True RMS
60.00 AAC
0.01A
±(2.8% + 8 digits)
600.0 AAC
0.1A
±(3.0% + 8 digits)
DC Current
60.00 AAC
0.01A
±(2.8% + 5 digits)
600.0 ADC
0.1A
±(3.0% + 5 digits)
AC Voltage True RMS
6.000 VAC
0.001V
±(1.8% + 8 digits)
60.00 VAC
0.01V
600.0 VAC
0.1V
DC Voltage
600.0 mVDC
0.1mV
±(1.5% + 2 digits)
6.000 VDC
0.001V
60.00 VDC
0.01V
600.0 VDC
0.1V
Resistance
600.0Ω
0.1Ω
±(1.0% + 4 digits)
6.000kΩ
0.001kΩ
±(1.5% + 2 digits)
60.00kΩ
0.01kΩ
600.0kΩ
0.1kΩ
6.000MΩ
0.001MΩ
±(2.5% + 3 digits)
60.00MΩ
0.01MΩ
±(3.5% + 5 digits)
Capacitance
40.00nF
0.01nF
±(4.0% + 20 digits)
400.0nF
0.1nF
±(3.0% + 5 digits)
4.000µF
0.001µF
40.00µF
0.01µF
400.0µF
0.1µF
±(4.0% + 10 digits)
4000µF
1µF
±(5.0% + 10 digits)
Frequency
10Hz to 10kHz
0.01Hz to 0.01khz
±(1.5% + 2 digits)
Sensitivity: 15Vrms
Duty Cycle
0.5% to 99.0%
0.1%
±(1.2% + 2 digits)
Pulse width: 100μs to 100ms, Frequency: 10Hz to 10kHz
Temperature Type K
-4 to - 1400°F
0.1° <800°; 1° >800°
±3% reading + 9°F/5°C
-20 to 760°C
0.1° <400°; 1° >400°
Specification does not include probe accuracy